Automatic translation of a transcript from Tonindustrie-Zeitung und Keramische Rundschau Volume 56 (1932) page 412-413
See also the German original and the discussion.

A New Slide Rule for Ceramics

By H. Klaus and Dr. W. Miehr

  As several articles in the specialist journals1) have shown, ceramic companies are also striving to simplify and mechanize frequently repetitive calculations (e.g., shrinkage calculations, model calculations, etc.). So far, this has been attempted by creating tables and by graphical representations; however, these methods do not yet represent a satisfactory solution, as they still require too much time and effort, and errors can too easily creep in.
  Therefore, it will likely be of general interest how all such tasks can be solved in a very short time and in a very simple way with the help of the ceramic slide rule (D.R.P.a) described below.
  The new slide rule includes, in addition to the standard scales for multiplication, division, etc., four scales specially designed for ceramic applications: A1, A2, S1, and S2 (see Figure 1).

Figure 1
Figure 1

  The special scales are related to the normal scales in certain mathematical relationships. For example, if one locates a number (a) on the main scale of the stick (scale O1/O2) and aligns a smaller number (b) on the tongue scale (U1/U2) with it, then (by setting the cursor to the endpoint of the tongue scale) one simultaneously obtains a) on scale S1 the difference of the two numbers, expressed as a percentage of the larger number, formula
(a − b)
a
·100.
b) on scale A1 this difference, expressed as a percentage of the smaller number, formula
(a − b)
b
·100.
c) on scale S2 the difference of the cube roots of the two numbers, expressed as a percentage of the cube root of the larger number.
Formula:
³√a − ³√b
³√a
·100   (or converted: (1 − ³√b/a) · 100);
d) on scale A2 the difference of the cube roots of the two numbers set on the main scales, expressed as a percentage of the cube root of the smaller number.
Formula:
³√b − ³√a
³√a
· 100   (or converted: (³√b/a − 1) · 100).

  All these formulas frequently appear in ceramic calculations.
  It would take up too much space to list all the possible applications of the ceramic slide rule here; only a few will be highlighted:

I. Determination of the porosity P from the specific gravity s and the bulk density r
a) Formel:   P = (s − r) ·100
s
%
b) The specific gravity s (= 2.70) is located on the main scale (scales O1 and O2 in Figure 1) and aligned with the bulk density r (= 2.30) on the tongue scale (scales U1 and U2). The cursor is then set to the endpoint of the tongue scale and the porosity P is read on scale S1 (P = 14.8%).

II. Determination of the percentage shrinkage Sl from the length of the freshly formed object (l) = 13.5 cm and the length of the fired object (lg) = 11.5 cm.
1. Shrinkage, expressed as a percentage of the mold size l 2)
Formula:
Sl = l − lg
l
·100%
= 13.5 − 11.5
13.5
·100% = 14.8%
One aligns l on the main scale of the staff with lg on the tongue and reads the value on scale S1:
    Sl = 14.8%

2. Shrinkage, expressed as % of firing size lg 3)
Formula:
Sl'=l − lg
lg
·100%
= 13.5 − 11.5
11.5
·100% = 17.4%
Setting as in 1; the result is read on scale A1.

III. The shrinkage Sl of a mass is given as a percentage of the mold size: it is to be expressed as a percentage of the firing size.
  Let Sl be 14.8%, find Sl'.
a) Formula:
Sl' = Sl · 100
100 − Sl
= 14.8 · 100
85.2
= 17.4%
b)On the ceramic slide rule, this calculation is performed by simply reading the value using the cursor: Find Sl (= 14.4) on scale S1 and read Sl' on scale A1 (See Figure 1) Sl' = 17.4%.
Conversely, Sl can of course also be determined from Sl'; the formula is then:
Sl = Sl' · 100
100 + Sl
%
  In this case, Sl' is located on scale A1 and Sl is read from scale S1.

IV. The volume shrinkage Sv is to be calculated from the linear shrinkage Sl (= 5.2%). The shrinkage is given as a percentage of the mold size.
a) Formula:
Sv = 3 Sl − 3 Sl²
100
+ Sl³
100²
= 3 · 5.2 − 3 · 5.2²
100
+ 5.2³
100²
= 15.6 − 0.81 + 0.01 = 14.80%
b)Locate Sl (5.2) on the S2 scale of the slide rule and read the value directly below it on the S1 scale:
    Sv = 14.8%. (Figure 1)
The following two examples relate to the investigation of refractory bricks.

V. Determination of the post-shrinkage from the bulk density of the object upon delivery (r0) and the bulk density of the post-burned object (r1).
a) The formula is then:
    Linear shrinkage NS = 100 (1 − ³√r0/r1) %
b) r1 is located on the main scale of the body and aligned with r0 on the slide scale. The following readings are taken:
  on scale S1: volume shrinkage;
  on scale S2: linear shrinkage. For r0 = 1.61 and r1 = 1.89 one obtains NS = 5.2% (Figure 1).

VI. Similarly, the percentage regrowth is determined from the bulk density of the object in its initial state (r0) and that of the re-burned object (r1).
a) Formula: Linear growth NW = 100 · (³√r0/r1 − 1) %
b) One locates r0 on the main scale of the staff and r1 on the tongue scale, brings them into alignment, and obtains
  auf Skala A1: Volume growth
  auf Skala A2: Linear growth
For r0 = 1.96 and r1 = 1,67 one obtains NW = 5.5 % (Figure 1)

VII. Determination of the percentage water content:
1. in % of wet mass.
2. in % of dry mass.
  Weight of the wet mass: Gf,
  Weight of the dried mass: Gt.
1. Formula:
Gf − Gt
Gf
·100%
2. Formula:
Gf − Gt
Gt
·100%
Gf is located on the main scale of the slide rule and aligned with Gt on the slide. The result is:
1. on scale S1: Water content in % of wet mass,
2. on scale A1: Water content in % of dry mass.

VIII. Determining the sizes (l, l1, l2, etc.) of shapes from the sherd dimensions (lg, lg1, lg2, etc.) and the shrinkage (Sl).
1. The shrinkage is given as a percentage of the mold size.
Formula:
100 · lg
100 − Sl
Sl is located on scale S1, the slide is adjusted to it, and for the values lg, lg2 etc. on the tongue, the corresponding values l1, l2, etc. are read on the main scale of the slide rule.
2. The shrinkage is given as a percentage of the firing size.
Formula:
lg · (100 + St)
100
Sl is located on scale A1; Reading as in 1.
  Other uses include:
  Determination of water absorption capacity, percentage loss on firing, dimensional accuracy; conversion of analyses from crude to burnt substance, etc.
  All these calculations require only one setting.
  As mentioned in the introduction, the ceramic slide rule can of course also be used for multiplication and division; it is also suitable for squaring, extracting roots, and performing logarithmic calculations. A special arrangement of the relevant scales achieves twice the accuracy of conventional slide rules.
 Since the back contains a table on the back showing the most important molecular weights for the ceramicist, it is particularly suitable for calculating glazes, frits, etc. from Seger formulas and conversely for calculating the Seger formula from the offsets.
  In summary, it can be said that the "Klaus ceramic slide rule" described above represents an important tool for the laboratory and business due to its versatile applications.
  Since each slide rule comes with detailed instructions and numerous calculation examples, no prior knowledge is required. The ceramic slide rule has been in use for years at the Central Laboratory and Research Institute of the Didier-Concern in Stettin; its many advantages have prompted us to make it available to the general public at a low price. (Information and exclusive distribution through the aforementioned institute, Stettin, P.O. Box 51.) For further details, please refer to the original publication in the „Keramischen Rundschau" Nr. 9, 40. Jhg. 1932.

1) Keramische Rundschau Nr. 16, 1930; Sprechsaal Nr. 48 and 49, 1927
2) Mold size = size of the freshly molded object
3) Firing size = size of the fired object